ABS concealed fan coil unit with air blower
Product Details
Product Introduction:
The ABS‑type concealed fan coil unit is a horizontal, concealed terminal device specifically engineered for high‑standard acoustic environments and stringent air quality requirements. The unit features a dual‑inlet, forward‑curved multi‑blade centrifugal impeller made of premium engineering plastic (ABS), replacing conventional galvanized steel impellers and fundamentally addressing issues such as corrosion, dust accumulation, and elevated airflow noise that can arise with metal impellers. The entire unit is installed within the suspended ceiling and is widely used in upscale hotels, hospital wards, cleanrooms, high‑end office buildings, and other settings where quietness is of paramount importance.
Main functions of the Products:
1. Silent Operation: The core ABS impeller is manufactured via precision injection molding, featuring smooth, burr-free flow passages and low aerodynamic noise. Paired with a three-speed, low-noise motor, the system’s overall noise level is significantly lower than that of conventional metal‑impeller units.
2. Corrosion-resistant and moisture-proof: The ABS wind wheel boasts exceptional resistance to acids and alkalis as well as outstanding moisture tolerance, ensuring it remains free from rust and deformation even during the plum rain season in southern China, in coastal areas with high salt‑fog exposure, or in environments with mildly corrosive gases, thereby delivering a long service life.
3. Efficient Cooling and Heating: Using a standard central air-conditioning chilled and hot water system, the heat-exchange coils deliver high efficiency, and when paired with a thermostat and motorized valve, they enable precise zone‑by‑zone temperature control.
4. Clean Supply Air: The unit’s return air grille is standardly equipped with a coarse‑efficiency filter. Combined with the smooth surface of the ABS impeller, which resists dust accumulation, this configuration is particularly well suited for applications that demand a certain level of air cleanliness.
5. Stable and vibration-free: The ABS wind wheel is lightweight and boasts high dynamic balancing accuracy, resulting in minimal vibration during operation and effectively preventing secondary noise caused by ceiling resonance.
6. Energy-saving adaptation: Standard equipment includes a single-phase, three-speed tapped motor, which can be upgraded to a DC brushless EC motor for stepless speed control and enhanced energy efficiency.
Product model specifications:
| Model number |
Air volume (m³/h) |
Cooling capacity (kW) |
Heating capacity (kW) |
Noise dB(A) |
Motor power (W) |
Water resistance (kPa) |
Inlet and outlet pipe diameter |
External dimensions (L×W×H) mm |
Net weight (kg) |
| FP-34WA-ABS |
350 |
1.85 |
3.10 |
≤33 |
30 |
16 |
DN20 |
750×450×230 |
17 |
| FP-51WA-ABS |
520 |
2.75 |
4.60 |
≤35 |
43 |
19 |
DN20 |
850×450×230 |
20 |
| FP-68WA-ABS |
690 |
3.65 |
6.10 |
≤37 |
52 |
23 |
DN20 |
950×450×230 |
23 |
| FP-85WA-ABS |
860 |
4.55 |
7.60 |
≤39 |
68 |
27 |
DN20 |
1050×450×230 |
27 |
| FP-102WA-ABS |
1030 |
5.45 |
9.10 |
≤41 |
92 |
31 |
DN20 |
1150×450×230 |
31 |
| FP-136WA-ABS |
1370 |
7.25 |
12.1 |
≤43 |
130 |
36 |
DN25 |
1350×500×250 |
37 |
| FP-170WA-ABS |
1710 |
9.05 |
15.1 |
≤45 |
168 |
39 |
DN25 |
1550×500×250 |
43 |
| FP-204WA-ABS |
2050 |
10.9 |
18.2 |
≤47 |
205 |
43 |
DN25 |
1750×550×270 |
51 |
Keywords:
Quote Inquiry
Please fill in your Contact information and your requirements; we will arrange for a professional to contact you!
Cross-flow air curtain machine
The cross‑flow air curtain employs a large‑diameter, slender cross‑flow impeller—also known as a tangential fan—directly driven by a single‑phase motor to generate a wide, planar, high‑velocity airflow. It is installed above or on the side of doorways. The unit features a flat, rectangular profile with a much reduced depth compared to centrifugal models, allowing it to seamlessly integrate into various ceiling designs. It is particularly well suited for spaces with limited headroom and where aesthetics and quiet operation are paramount, such as shopping malls, supermarkets, restaurants, office buildings, banks, hospitals, and residential garages.
Our company’s surface-type coolers are among the core heat-exchange devices in air-conditioning and ventilation systems. They are primarily used to cool and dehumidify air, and can also be switched to hot-water or steam mode during winter to provide air heating. By utilizing a refrigerant (such as chilled water, refrigerant, or brine) or a heat-transfer medium (such as hot water or steam) flowing inside the tubes, these units facilitate forced‑convection heat exchange with the air flowing outside the tubes, thereby regulating air temperature and humidity. As the central heat-exchange components of chiller units, fresh-air handling units, fan coil units, and other equipment, they offer high heat-exchange efficiency, flexible installation, and broad compatibility.
The ceiling‑mounted fresh air ventilator (ceiling‑type air handling unit) is a central air‑conditioning terminal unit that integrates fresh air exchange, air temperature and humidity control, air filtration and purification, and energy recovery. The unit features a concealed ceiling‑mount installation, suspended within the building’s suspended ceiling. It utilizes chilled water or hot water piping to provide cooling and heating, while simultaneously exhausting indoor stale air and supplying filtered outdoor fresh air. This system not only enhances indoor air quality in enclosed spaces but also regulates air temperature through heat‑exchanger coils, offering both ventilation and central air‑conditioning functions. It delivers energy savings, minimizes floor space occupation, and is widely suited for integration into fresh air systems in commercial, industrial, and large public buildings.
Our company’s Q‑type air heater is an industrial‑grade, forced‑convection heating unit that uses water or steam as the heat transfer medium. It is specifically designed for large‑space applications such as factory and mine workshops, warehouses, large buildings, and drying rooms. The equipment consists of a fan, an electric motor, and a steel finned‑tube radiator integrated into a single unit. Performance tests have demonstrated its stable and reliable operation. By combining “steam heat exchange with forced air supply,” it rapidly heats the air, delivering highly efficient heating and making it one of the mainstream solutions for heating high‑ceiling spaces.