SHANDONG DELIN

Dual-flow ventilation unit


Dual-flow ventilation unit
Dual-flow ventilation unit
Dual-flow ventilation unit
Dual-flow ventilation unit
+
  • Dual-flow ventilation unit
  • Dual-flow ventilation unit
  • Dual-flow ventilation unit
  • Dual-flow ventilation unit

Product Details

Product Overview:
    Our company manufactures bidirectional fresh-air ventilators—also commonly referred to as fresh-air ventilation units—which are integrated ventilation and air-purification devices that combine mechanical supply and exhaust airflow. They simultaneously facilitate a two-way air circulation by introducing fresh outdoor air while expelling stale indoor air, thereby achieving efficient indoor–outdoor air exchange.
It continuously supplies filtered, clean fresh air to the indoor space via its built-in fan and filtration system, while simultaneously exhausting indoor pollutants such as carbon dioxide, formaldehyde, odors, and PM2.5, thereby addressing ventilation challenges in enclosed spaces and enhancing indoor air quality. Some models equipped with a total heat recovery function can also reclaim the cooling or heating energy from exhaust air, reducing the energy consumption of the HVAC system and balancing ventilation needs with energy efficiency, making them suitable for a wide range of residential, commercial, and industrial applications.

Product specification and model reference:
The specifications of bidirectional fresh-air ventilators are primarily categorized based on their rated airflow. Common specifications for residential and commercial models are as follows:

Airflow specifications ( m³/h)

Applicable Scenarios

Typical Parameter Reference

150~250

Small-sized homes, apartments

Power 40–80 W, noise level ≤ 35 dB(A), connection pipe diameter φ100–125 mm

350~500

Large-sized residential units, small commercial shops

Power 80–150 W, noise level ≤ 40 dB(A), connection pipe diameter φ150–160 mm

600~1000

Office, restaurant, small and medium-sized

Power 150–300 W, noise level ≤ 45 dB(A), connection pipe diameter φ160–200 mm

More than 1,000

Large shopping malls, factories, and office buildings

Power 300W and above; customizable airflow and static pressure, suitable for large-scale ventilation systems.

Note: Model naming conventions vary across brands. For example, brands such as Lüdaofeng and Huandu Tupu use a combination of airflow rate, functionality (e.g., total heat recovery / unidirectional flow), and installation type (ceiling‑mounted / floor‑standing) to designate their models. For instance, “ERV‑D350” denotes a ceiling‑mounted fresh air ventilator with a 350 m³/h airflow rate and total heat recovery.

Scope of Product Use:
Bidirectional ventilation units are suitable for a wide range of applications, primarily including the following categories:
1. Residential and Home Scenarios:
Various types of market-rate homes, villas, apartments, and more—especially in areas where windows cannot be opened for ventilation after renovation or where outdoor air quality is poor—can achieve 24-hour silent ventilation, effectively removing formaldehyde and unpleasant odors while enhancing residential comfort.
2. Commercial Office Scenarios:
In high-occupancy spaces such as office buildings, offices, and meeting rooms, it effectively reduces indoor carbon dioxide levels, alleviates “air-conditioning illness” and the symptoms of oxygen deficiency and dizziness associated with enclosed environments, and enhances workplace productivity.
3. Commercial Service Scenarios:
In restaurants, hotels, gyms, beauty salons, KTVs, and other venues, it can swiftly remove cooking fumes, unpleasant odors, and excess moisture, improving indoor air quality while reducing air-conditioning energy consumption.
4. Special Use Cases:
In facilities such as hospitals, laboratories, school classrooms, underground spaces, archives, and computer rooms—where air cleanliness and ventilation rates are subject to stringent requirements—certain custom‑designed models can meet specialized operational needs, including corrosion resistance, explosion protection, and high static pressure.


Keywords:

Quote Inquiry

Please fill in your Contact information and your requirements; we will arrange for a professional to contact you!

  • How many products do you need?
  • What more information do you need to know?
Submit

Cross-flow air curtain machine


The cross‑flow air curtain employs a large‑diameter, slender cross‑flow impeller—also known as a tangential fan—directly driven by a single‑phase motor to generate a wide, planar, high‑velocity airflow. It is installed above or on the side of doorways. The unit features a flat, rectangular profile with a much reduced depth compared to centrifugal models, allowing it to seamlessly integrate into various ceiling designs. It is particularly well suited for spaces with limited headroom and where aesthetics and quiet operation are paramount, such as shopping malls, supermarkets, restaurants, office buildings, banks, hospitals, and residential garages.

Cooling coil


Our company’s surface-type coolers are among the core heat-exchange devices in air-conditioning and ventilation systems. They are primarily used to cool and dehumidify air, and can also be switched to hot-water or steam mode during winter to provide air heating. By utilizing a refrigerant (such as chilled water, refrigerant, or brine) or a heat-transfer medium (such as hot water or steam) flowing inside the tubes, these units facilitate forced‑convection heat exchange with the air flowing outside the tubes, thereby regulating air temperature and humidity. As the central heat-exchange components of chiller units, fresh-air handling units, fan coil units, and other equipment, they offer high heat-exchange efficiency, flexible installation, and broad compatibility.

Fresh air ventilator


The ceiling‑mounted fresh air ventilator (ceiling‑type air handling unit) is a central air‑conditioning terminal unit that integrates fresh air exchange, air temperature and humidity control, air filtration and purification, and energy recovery. The unit features a concealed ceiling‑mount installation, suspended within the building’s suspended ceiling. It utilizes chilled water or hot water piping to provide cooling and heating, while simultaneously exhausting indoor stale air and supplying filtered outdoor fresh air. This system not only enhances indoor air quality in enclosed spaces but also regulates air temperature through heat‑exchanger coils, offering both ventilation and central air‑conditioning functions. It delivers energy savings, minimizes floor space occupation, and is widely suited for integration into fresh air systems in commercial, industrial, and large public buildings.

Q-type steam heater


Our company’s Q‑type air heater is an industrial‑grade, forced‑convection heating unit that uses water or steam as the heat transfer medium. It is specifically designed for large‑space applications such as factory and mine workshops, warehouses, large buildings, and drying rooms. The equipment consists of a fan, an electric motor, and a steel finned‑tube radiator integrated into a single unit. Performance tests have demonstrated its stable and reliable operation. By combining “steam heat exchange with forced air supply,” it rapidly heats the air, delivering highly efficient heating and making it one of the mainstream solutions for heating high‑ceiling spaces.