Product Details
Product Introduction:
Our company manufactures jet fans (tunnel jet fans), which are a specialized type of axial-flow fan. They are primarily used in longitudinal ventilation systems for highways, railways, subway tunnels, and similar underground structures, making them one of the most widely employed pieces of equipment in tunnel ventilation today.
1. It can be classified into unidirectional jet fans and reversible bidirectional jet fans. The bidirectional model delivers essentially equal forward and reverse airflow thrust, making it well-suited for bidirectional road tunnel applications.
2. Fans are typically installed either by suspension or on the sidewall, thereby not encroaching on the tunnel’s traffic space. They eliminate the need for additional ductwork, resulting in low civil‑engineering costs, and offer convenient installation, operation, and maintenance, making them a highly cost‑effective ventilation solution.
3. Most models are equipped with silencers, which effectively reduce operating noise and meet tunnel‑specific noise‑control requirements, while also offering corrosion resistance, stable operation, and high reliability.
Main functions of the Products:
1. Daily tunnel ventilation: Supplies fresh air into the tunnel, removes harmful gases such as carbon monoxide and nitrogen oxides generated by vehicle traffic, reduces dust concentrations, and ensures that the tunnel’s air quality meets regulatory standards.
2. Smoke Exhaust and Temperature Control During Fire Conditions: In the event of a tunnel fire, smoke flow can be directed to control its spread, thereby ensuring safe conditions for evacuation and firefighting operations, while also reducing tunnel temperatures and mitigating the risks posed by high heat to both the tunnel structure and personnel.
3. Improve air flow within the tunnel: By leveraging the entrainment effect of jet flows, induce overall air movement throughout the tunnel, addressing issues of stagnant air and inadequate local ventilation, and ensuring uniform airflow distribution.
General Technical Parameters Table (Reference for Typical Specifications of the SDS Series):
Parameters may vary across different models and manufacturers; the following are typical parameter ranges commonly used in the industry:
| Parameter Item |
General Specification Range |
Explanation |
| Air volume |
10,000 ~ 430,000 m³/h |
Different models correspond to different airflow ranges, enabling them to meet the requirements of tunnels with varying lengths and cross-sectional dimensions. |
| Outlet air velocity |
20 ~ 35 m/s |
Determining the jet-induced capability of the fan |
| Thrust |
100 ~ 3500 N |
Some models can generate bidirectional thrust, with reverse thrust no less than the forward thrust. 90% |
| Motor power |
5.5 ~ 110 kW |
Motor protection class IP54 and above, insulation class F, temperature rise class B. |
| Rotational speed |
960 ~ 2900 r/min |
Mostly 4-pole or 6-pole motors, suitable for varying airflow and pressure requirements. |
| Noise |
60 ~ 80 dB(A) |
After installing a silencer, further reduction can be achieved. |
| Operating temperature |
-20 ~ 60℃ |
The fire‑service‑specific model can withstand 250℃/300℃ high temperature (for 1 hour) |
| Installation method |
Lifting and side wall installation |
Adaptable to various tunnel installation spaces |
| Material |
Carbon steel (standard) / Stainless steel (optional) |
Apply an anti-corrosion coating to the carbon steel surface to extend its service life. |
Note: The specific fan model and parameters for each project must be custom-selected and designed by the manufacturer, taking into account tunnel length, cross-sectional dimensions, traffic volume, and fire‑safety requirements.
Keywords:
Quote Inquiry
Please fill in your Contact information and your requirements; we will arrange for a professional to contact you!
Cross-flow air curtain machine
The cross‑flow air curtain employs a large‑diameter, slender cross‑flow impeller—also known as a tangential fan—directly driven by a single‑phase motor to generate a wide, planar, high‑velocity airflow. It is installed above or on the side of doorways. The unit features a flat, rectangular profile with a much reduced depth compared to centrifugal models, allowing it to seamlessly integrate into various ceiling designs. It is particularly well suited for spaces with limited headroom and where aesthetics and quiet operation are paramount, such as shopping malls, supermarkets, restaurants, office buildings, banks, hospitals, and residential garages.
Our company’s surface-type coolers are among the core heat-exchange devices in air-conditioning and ventilation systems. They are primarily used to cool and dehumidify air, and can also be switched to hot-water or steam mode during winter to provide air heating. By utilizing a refrigerant (such as chilled water, refrigerant, or brine) or a heat-transfer medium (such as hot water or steam) flowing inside the tubes, these units facilitate forced‑convection heat exchange with the air flowing outside the tubes, thereby regulating air temperature and humidity. As the central heat-exchange components of chiller units, fresh-air handling units, fan coil units, and other equipment, they offer high heat-exchange efficiency, flexible installation, and broad compatibility.
The ceiling‑mounted fresh air ventilator (ceiling‑type air handling unit) is a central air‑conditioning terminal unit that integrates fresh air exchange, air temperature and humidity control, air filtration and purification, and energy recovery. The unit features a concealed ceiling‑mount installation, suspended within the building’s suspended ceiling. It utilizes chilled water or hot water piping to provide cooling and heating, while simultaneously exhausting indoor stale air and supplying filtered outdoor fresh air. This system not only enhances indoor air quality in enclosed spaces but also regulates air temperature through heat‑exchanger coils, offering both ventilation and central air‑conditioning functions. It delivers energy savings, minimizes floor space occupation, and is widely suited for integration into fresh air systems in commercial, industrial, and large public buildings.
Our company’s Q‑type air heater is an industrial‑grade, forced‑convection heating unit that uses water or steam as the heat transfer medium. It is specifically designed for large‑space applications such as factory and mine workshops, warehouses, large buildings, and drying rooms. The equipment consists of a fan, an electric motor, and a steel finned‑tube radiator integrated into a single unit. Performance tests have demonstrated its stable and reliable operation. By combining “steam heat exchange with forced air supply,” it rapidly heats the air, delivering highly efficient heating and making it one of the mainstream solutions for heating high‑ceiling spaces.